Ecovac Services / Projects / Gasoline / |
SITE LOCATION: |
Russellville, Alabama |
CONTAMINATION: |
Separate-phase hydrocarbons (SPH - gasoline) in three wells ranging in thickness from 0.02 to 0.20 feet |
HYDROGEOLOGY: |
Groundwater is present in silty clay at ~3 to 7 feet below grade |
SURFAC®/ISCO-EFR ® EFFECTIVENESS: |
SPH is not present and dissolved BTEX levels are well below corrective action limits (CALs) |
Gasoline SPH has been historically present in three monitor wells for a number of years. Three mobile dual-phase extraction events conducted by another provider failed to remove SPH at the site.
Hydrogeology
Groundwater is present in silty clay at depths ranging from approximately 3 to 7 feet below grade.
EcoVac Services was contacted to implement SURFAC® and ISCO-EFR® at this site to remove SPH and reduce BTEX concentrations below the site’s CALs.
EcoVac Services’ patented SURFAC® and ISCO-EFR® processes are the combination of surfactant and oxidant injection, respectively, with dual-phase/multi-phase extraction. The processes described herein are patent-protected and represent the intellectual property of EcoVac Services, Inc.
SURFAC® and ISCO-EFR® Implementation
A single SURFAC® application was implemented at the site in September and October 2007 (four field days) to remove SPH from three monitor wells. ISCO-EFR® was implemented in July 2008 and October 2009 (a total of four field days) to reduce BTEX concentrations in four monitor wells to below CALs.
A single SURFAC® application successfully removed SPH from this site (four field days).
ISCO-EFR® reduced BTEX concentrations to well below the site’s CALs (four field days). A percent reduction in BTEX concentrations was achieved by ISCO-EFR®.
Table 1: ISCO-EFR® Results
Date |
Well Ids |
B (ug/l) |
T (ug/l) |
E (ug/l) |
X (ug/l) |
Prior to ISCO-EFR® |
MW-1 MW-2 MW-3 MW-4 |
2,705 1,191 2,018 3,652 |
2,138 698 2,584 8,173 |
2,138 1,615 1,664 2,042 |
7,940 2,945 7,005 10,308 |
Post ISCO-EFR® |
MW-1 MW-2 MW-3 MW-4 |
1324 175 890 1,117 |
1,630 170 1,851 5,815 |
1,630 605 1,406 1,146 |
6,971 1,468 6,174 6,654 |
Post ISCO-EFR® |
MW-1 MW-2 MW-3 MW-4 |
11 ND ND 56 |
152 ND 18 26 |
152 ND 116 17 |
157 ND 464 8 |